Get a quote

Coking Waste Heat Boiler In Colombia

  • unit conversion: ton of refrigeration to horsepower - HVAC

    Feb 18, 2005 · 1 boiler hp = 33475 btu/hr cooling tons is normally not converted to hp using 12000/2545 = 4.89. Instead the KW compressor input is used and if desired converted to hp. The compressor does not transform elect to cooling tons. Instead the compressor is used to transfer heat from one medium (air or water) to the refrigerant and then reject the Learn More

  • Steam Calculators: Boiler Calculator

    Mar 17, 2015 · Steam, Boiler, and Blowdown Pressure are the same. Combustion Efficiency is the % of fuel energy that is directly added to the feedwater and not otherwise lost or used. Blowdown Rate is the % of incoming feedwater mass flow rate that leaves the boiler as a saturated liquid at boiler pressure.Learn More

  • CONVERSION OF BOILER IN KG/H AND KW

    CONVERSION OF BOILER IN KG/H AND KW (Approximate) G.B. and U.S.A. Steam from and at 100°C Boiler HP Kg/h 2.26MJ/kg Metric System Steam from 0°C to 100°C Kg/h 2.26MJ/kg Power In kW 1 5 10 15 20 30 40 50 60 70 80 100 150 200 250 …Learn More

  • hp(S) - Horsepower, Boiler. Conversion Chart / Units of

    This is a conversion chart for horsepower, boiler (Common Units). To switch the unit simply find the one you want on the page and click it. You can also go to the universal conversion page. 2: Enter the value you want to convert (horsepower, boiler). Then click the Convert Me button. Your value gets instantly converted to all other units on the Learn More

  • M Indra Setiawan - Sales Branch Manager III Area Jatim

    1.1 HOC Section (Delay Coking Unit, Distillate Hydrotreating, High Vacuum Unit, & Waste Heat Boiler) • Monitoring mass balance, heat balance, energy consumption, & critical variable. • Monitoring, troubleshooting, and developing stream of product. • Providing equipment and catalyst performance calculation.Learn More

  • How to calculate steam boiler capacity?-ZBG Boiler

    Jul 28, 2016 · 2.) rated boiler horsepower (BHP- One bhp is the evaporation of 34.5 pounds (= 15.648 kg) of water per hour from a temperature of 212oF (=100oC) into dry saturated steam at the same temperature. Equivalent to 33,472 BTU/h (= 35.291 MJ/h).)Learn More

  • STEAM DRUM WATER LEVEL MEASUREMENT

    1. (PG60.1) All boilers having a fixed water level (steam and water interface) shall have at least one gage glass (a transparent device that permits visual determination of the water level). 2. (PG‐60.1.1) Boilers having a maximum allowable working pressure exceeding 400 psi (3 MPa)Learn More

  • It Tons Of Refrigeration to Boiler Horsepower | Kyle's

    Unit Descriptions; 1 Ton of Refrigeration (IT): Defined as 1 BTU IT x 1 sh tn/lb / 10 min/s. Approximately 3.516853 x 10 3 Watts (SI).: 1 Horsepower (boiler): The energy rate needed to evaporate 34.5lb of water at 212 °F (100 °C) in one hour.Learn More

  • Water treatment of steam boilers - SlideShare

    Aug 02, 2015 · Low pressure boilers operate at 15 psig or below. Boiler capacity Boiler capacity is expressed in the following units. 1. Horse Power. 2. Pounds of Steam per Hour 3. BTU per Hour 1HP means energy to convert 34.5 pounds of water to steam from (and at) 212o F at sea level. High pressure boiler treatment The treatments for high pressure boilers Learn More

  • Unit Conversion--How to Calculate Boiler Horsepower

    Boiler Horsepower - BHP. The Boiler Horsepower (BHP) is the amount of energy required to produce 34.5 pounds of steam per hour at a pressure and temperature of 0 Psig and 212 ℉, with feedwater at 0 Psig and 212 ℉. "Boiler horsepower, a unit of measurement of power of steam boilers" from Wiki.Learn More

  • Fuel and Energy Conversion and Equivalence Chart

    Coal 28,000,000/ton 1 Barrel of Oil = 42 Gallons 1 Btu = 252 calories 1 Btu = .293 watt 1 ton of refrigeration = 12,000 Btu/hr 1lb residential garbage = 2,500 Btu 1lb coal = 12,000 Btu 1lb wood = 3,500 Btu 1hp = 746 watts 1hp = 33,479 Btu/hr (boiler)Learn More

  • BTUs per Hour (Btu/h) To Boiler Horsepower (hp(S), steam

    This is a free online BTUs per Hour (Btu/h) to Boiler Horsepower (hp(S), steam) conversion calculator. You can convert power from BTUs per Hour (Btu/h) to Boiler Horsepower (hp(S), steam) instantly using this tool.Learn More

  • Convert Boiler horsepower to Tons of refrigeration

    Convert Horsepower to Ton (refrigeration)Learn More

  • Boiler Ratings | Spirax Sarco

    A boiler horsepower is not the commonly accepted 550 ft lbf/s and the generally accepted conversion factor of 746 Watts = 1 horsepower does not apply. USA and Australia In the USA and Australia the readily accepted definition of a boiler horsepower is the amount of energy required to evaporate 34.5 lb of water at 212°F atmospheric conditions.Learn More

  • 50 HP Boiler Models | Cleaver-Brooks | York-Shipley

    50 HP boilers are used in all types of applications throughout the United States. Although vertical boilers are available at this capacity, most industrial plants elect to go with a horizontal firetube boiler. The horizontal firetube boiler offers a much longer lifespan, safer operation and more stable firing. 50 HP boilers can be purchased in Learn More

  • Convert MBH to Horsepower (boiler)

    Instant free online tool for MBH to horsepower (boiler) conversion or vice versa. The MBH to horsepower (boiler) conversion table and conversion steps are also listed. Also, explore tools to convert MBH or horsepower (boiler) to other power units or learn more about power conversions.Learn More

  • Boiler Horsepower to Tons Of Air Conditioning | Kyle's

    Boiler Capacity - Engineering ToolBoxLearn More

  • The Boiler-Commissioning Process | HPAC Engineering

    Jan 09, 2013 · The Boiler-Commissioning Process. Jan. 9, 2013. When the boiler commissioning process works well, it is a win for everyone: The owner gets a quality system that works efficiently and can be maintained easily, the commissioning agent's close relationship with the engineer of record and links to the builder's request-for-information process Learn More

  • How To Calculate Natural Gas Boiler Consumption--ZBG

    The boiler gas consumption calculation need the following parameters: such as natural gas calorific value 8500kcal/m3, pressure 8-10Kpa, and theoretically, the gas consumption of boiler heat = boiler calorific value÷ (Calorific value of natural gas x Boiler thermal efficiency )= 2400 000 Kcal / (8500Kcal * 0.94) =297m3/h, here we take 4 tons Learn More

  • Steam Boiler Feed Pumps & High Pressure Boiler Feed Water

    Industrial boilers, for example on board a marine vessel, in a large industrial factory or power plant, are fed either fresh water or steam by a high pressure boiler feed pump. As the water or steam is fed round a system, they are sometimes referred to as boiler circulation pumps.Learn More

Provide you with the most suitable plan and price

Start your project